What the messages mean, whether anything was written to the inverters, what to do, and how sure we are. “Observed” means we saw it on our own systems and read the device state afterwards from a fresh download. “Documented” means the meaning comes from Victron documentation or community posts and we have not seen it ourselves.
The single most useful rule in this file: if an upload is rejected and you are not sure why, download a fresh copy from the device, then upload that (edited or not). Most rejections we hit were mk2vsc-36 on archived files; a fresh download of the same system was accepted every time (see mk2vsc-36).
The mk2vsc-NN codes come from the MK2/MK3 protocol layer that parses the uploaded file on the GX or
inverter side, not from the VEConfigure program. They are verdicts on the bytes.
On a settings-only upload the file is refused and the settings are not applied. What the device objects to is not fully established; the record below is what we hold.
Observed rejections of archived files. System A 2026-08-12: right after a hand-built file carrying
assistant records and grid-code words had been accepted into the install dialog and refused at commit, the
archived bare baseline (system_a_2026-08-12_download_bare_deviceform_1, settings 190/191 = 0xffff) was
refused repeatedly across two GX reboots; the fresh downloads taken then (..._2, ..._3) carry settings
190/191 = 0xfff5/0xff00 on both inverters, so the device had written its grid-code words during the
attempt, and uploading that fresh download unmodified was accepted at once. System C 2026-07-20: after the
half-applied install (VE.Bus error 10), every pre-incident file was refused; the post-incident download
(system_c_2026-07-20_download_half-ess_deviceform_5) carries 190/191 = 0xfff5/0x0000 where the refused
files carry 0xffff/0xffff.
Observed rejections at the grid-code step. System C 2026-07-20 and System A 2026-08-12, after the “Resetting VE.Bus products” dialog of a hand-built assistant install (System A v4 carried grid-code words that differed from the device’s and was refused at commit, not up front).
What it is not. It is not a timestamp check. The u32 at block offset +0x4f (+0x59 in upload form) is
stamped when the file is generated (system_b_2026-09-04_download_ess_deviceform_1/2/3: unchanged content,
three increasing stamps), and on 2026-09-04 System B accepted the three-hour-old _1 after _2 had been
taken, and then system_b_2026-09-04_prepared_ess_deviceform_1 (the _2 content stamped 16:00, before a
file it had just accepted). Neither was refused.
Cause: Unknown. Two readings fit part of the record and neither fits all of it. (a) The first half of
the message is literal and a device-form file whose grid-code words (81, 128, 190, 191) disagree with the
device’s is refused: every refused archived file above carried words that differed from the device’s. But
on 2026-08-14 System A accepted a device-form bare rollback while it held an ESS install
(system_a_2026-08-14_download_ess_deviceform_1: 128 = 1 on both inverters, 191 = 1 and 257). The two
candidate rollback files are in the corpus (system_a_2026-08-14_prepared_bare_deviceform_1, words
0xffff/0xff00, and _2, words 1/0xff00); which one was uploaded, and that it was accepted, come from the
operator’s incident notes rather than from a re-download in the corpus (the next download, 08-19, matches
neither file: its charge profile is the pre-07-20 one, docs/HISTORY.md 2026-08-19, so the file that landed is
not in the corpus). Inferred, then: a device-form file with differing words
was not refused that day. (b) A transient state of the device in the minutes after an
interrupted install: both refusals of archived files happened within the same session as an install
attempt that ended at commit or in error 10, and the 08-14 acceptance came a day later. Reading (a) was
tested on 2026-09-04: a fresh System A device-form file with only setting 191 changed (0x0101 -> 0xff00,
both inverters) was not refused before the reset began: the dialog ran “Resetting VE.Bus products” and
ended in Error 1303 when the GX went offline (docs/HISTORY.md). Whether the device refused it at commit,
as it did System A’s v4 on 08-12, is Unknown until that system’s next download. A 191-only mismatch is
therefore not a pre-write gate, which rules out (a) as an up-front check; (a) as a commit-time check is
untested. Reading (b) is untested (an archived file uploaded long after any install attempt).
What to do: download fresh, rebuild your edit on that file, upload; a fresh download carries the device’s
current grid-code words. The writer refuses settings 81, 128, 129-189, 190 and 191 (fields.GRID_CODE_LOCKED). If the system is
in error 10, see below.
A pre-write reject: the parser could not match the blocks in the file to the inverters it discovered on the bus. Observed twice with different causes:
Device state: nothing written. What to do: check the device list in VRM for an “Unknown” serial first;
reboot the GX if so. Then check the file with mk2vsc validate and mk2vsc show (form must be “device”).
Confidence: observed.
A pre-write reject: the unit walk over the file found the wrong number of blocks. Observed four times,
always with a hand-built file: a wrong next-section pointer, a block shorter than the canonical length,
and blocks emitted in the wrong order so that the two-byte length prefix of the following section sat
after the wrong block. mk2vsc validate catches a broken pointer chain and bad checksums; it does not know the canonical block
length, so a structurally consistent but too-short block still passes it.
Device state: nothing written. What to do: run mk2vsc validate; if it passes and you still get this,
you have found a structural rule we do not know. Please open an issue with the file. Confidence: observed.
Seen when trying to download while the VE.Bus was re-enumerating after an interrupted install
(System C 2026-07-20, NumberOfMultis read as none on the GX). Wait for the device list to show all
inverters again, or reboot the GX. Device state: unchanged by the download attempt. Confidence: observed
once.
The GX cannot see the inverters over VE.Bus at this moment. Seen immediately after an upload that reset the VE.Bus (an assistant change from any source): the bus is re-enumerating. Nothing is wrong with the file. Wait a few minutes and download again; if it persists, check the VE.Bus cabling and the GX.
A VRM tunnel timeout, not a verdict on the file. Observed on both successful and failed uploads. The device may still be working: on System A 2026-08-12 the tunnel dropped at about two minutes while the device continued an install and telemetry stayed silent for twenty minutes. On System B 2026-07-24 it appeared after the inverter had already returned to inverting.
Device state: unknown until you download. What to do: wait, then download fresh and diff against what
you uploaded (mk2vsc diff uploaded.rvms fresh.rvms). If the verdict is “only bookkeeping”, the upload
took. Confidence: observed.
The VE.Bus write lock is held; a previous upload is still being processed. Observed once, about 13 minutes after an Error 1303 on an assistant install. Device state: mid-write. What to do: wait, do not retry, watch VRM for the inverters to reappear. Confidence: observed once.
The assistant program on an inverter is corrupt or inconsistent. Observed on System C 2026-07-20 after we uploaded a block with its assistant records truncated. The system dropped from ESS to pass-through and the inverter switched off; the stored file still showed the assistant present. Recovery: re-upload a fresh known-good file with the assistant intact, then reboot the GX. Confidence: observed.
We saw this in two situations: for about 17 minutes after an assistant install was interrupted at the grid-code step (System C 2026-07-20), and briefly while the two rocker switches on a pair were in different positions during a manual power cycle (System A 2026-08-13). The first is the half-configured state; the second is benign. Recovery from the first: GX reboots until all inverters re-enumerate, then upload a fresh known-good file. Confidence: observed; the official meaning is documented by Victron.
Observed on System A after hand-built ESS files whose header words were internally inconsistent with the assistant flag. Not an error code but a pattern. Recovery: upload a fresh bare download. Confidence: observed twice, mechanism inferred.
Observed on System A and System D after hand-built ESS files that stored correctly. Every restart lever failed (mode toggle, VE.Bus restart, GX reboot, rocker cold boot). Recovery: upload a fresh bare download; the installer’s GUI session later loaded a working assistant. See docs/ASSISTANTS.md section 7. Confidence: observed; cause hypothesised.
An assistant install (or removal) is in progress. The inverters will stop, the VE.Bus resets, and the system may take 15 to 20 minutes to re-enumerate. This is what distinguishes a settings-only upload (no dialog, no interruption, inverters keep running) from a structure-changing one. Do not interrupt it. Confidence: observed on every assistant install we witnessed.
You added the ESS assistant before setting a grid code. The order in VE.Bus System Configurator is: open the inverter, Grid tab, choose a grid code standard (needs the dealer password), send to all devices; then Assistants tab. “Switch as group” is often not displayed as a checkbox; it follows from the grid code state, so searching for it is futile. Confidence: observed on our Windows session and confirmed by community posts.
An assistant was added to the list but its wizard was not completed. Open it and finish every page. Confidence: observed.
.vsc that cannot be uploadedFile, Save As in VEConfigure writes a .vsc that only applies locally over an MK3 cable. Close the
inverter window and confirm instead; that updates the .rvms that Remote VEConfigure uploads.
Confidence: observed.
The upload was accepted. It is not proof the settings are right: download fresh and run mk2vsc diff
against what you uploaded, and mk2vsc check against your intent file. On 2026-08-14 a file with this
dialog reintroduced an out-of-spec charge voltage (docs/HISTORY.md).
| Message | Written? | First action | Confidence |
|---|---|---|---|
| mk2vsc-36 (no reset dialog seen) | no | download fresh, rebuild edit on it | observed |
| mk2vsc-36 (after “Resetting VE.Bus products”) | possibly partial | stop, GX reboot, fresh known-good upload | observed |
| mk2vsc-47 | no | check VRM device list for “Unknown”; GX reboot; check file form | observed |
| mk2vsc-49 | no | mk2vsc validate; fix pointers/order |
observed |
| mk2vsc-62 | n/a | wait for re-enumeration | observed once |
| Error 1303 | unknown | wait, download, diff | observed |
| Error 1391 | in progress | wait | observed once |
| VE.Bus error 6 | yes, corrupt program | fresh good file + GX reboot | observed |
| VE.Bus error 10 | half-configured or benign | reboot until enumerated, then fresh upload | observed |
| “Resetting VE.Bus products” | in progress | do not interrupt | observed |
| “switch as group” | n/a | set grid code first | observed + documented |
| “not all assistants configured” | n/a | finish the wizard | observed |